Use capsules Granulator In order to ensure the normal operation of equipment, improve production efficiency and ensure product quality, the following aspects should be paid attention to:
1、 Equipment placement and environmental requirements
Location: Capsule counting machine It shall be placed in a dry, ventilated place without direct sunlight to avoid damage to equipment caused by humid and high temperature environment.
Stability: ensure that the equipment is placed vertically and stably to avoid tilt and shaking affecting the counting accuracy.
2、 Preparation before operation
Check the equipment: before use, the equipment shall be comprehensively checked to ensure that the power line is well connected, the plug is properly grounded, and the air line (if applicable) has also been connected. At the same time, check whether the working table of the equipment is stable without tilting and shaking.
Debugging equipment: turn on the power switch of the equipment and wait for several minutes to ensure that the equipment is in normal working state. Then, according to the production demand, adjust the speed and vibration force of the equipment, as well as the subpackage volume, to ensure that the capsules can enter the several particle holes smoothly and count accurately.
3、 Precautions during operation
Power and air supply: ensure stable power and air supply (if applicable) during operation, and avoid equipment failure caused by sudden power failure or insufficient air supply.
Drug quality: put in Granulator The capsules must be completely locked, with uniform length, and free from moisture deformation or unqualified products. Otherwise, the counting accuracy and normal operation of the equipment may be affected.
Operation specification: during the operation, the operation steps in the equipment manual shall be strictly followed to avoid equipment damage or counting error caused by misoperation. At the same time, attention should be paid to the operation specifications to avoid accidental injuries caused by hands or other objects entering the equipment.
Observe the counting condition: during the operation of the full-automatic capsule counting machine, observe the counting condition of capsules at any time to ensure that the number of capsules in the counting holes is sufficient and evenly distributed. If it is found that the number of capsules in several holes is insufficient or unevenly distributed, it shall be timely sorted and adjusted with a brush and other tools.
4、 Maintenance
Cleaning equipment: after each use, the surface and interior of the equipment shall be cleaned in time to prevent dust and residues from affecting the next use effect. When cleaning, power off and unplug the power plug first, wipe the equipment surface with a clean soft cloth, and keep it ventilated and dry.
Check the parts: regularly check whether the parts of the equipment are damaged or worn, and timely replace them if damaged or worn. In particular, the height, spacing and other parameters of key components such as the counting disk and retaining ring shall meet the requirements to ensure the accuracy of counting.
Maintenance: regular Electronic granulator Carry out maintenance, such as lubricating transmission parts, fastening loose screws, etc., to extend the service life of the equipment and keep it in good working condition.
In conclusion, when using the capsule counting machine, attention should be paid to equipment placement and environmental requirements, preparation before operation, precautions during operation, maintenance and safety precautions and other aspects to ensure the normal operation of the equipment and product quality.